Outage Information
2025-06-09 20:15:19.985000
Automatic Outage: Radials older than 12 hours. Operator should investigate.
Automated Bot

2025-06-12 05:15:25.356000
2025-06-11 17:35:30 GMT seasonde Mike Trip and Lindsay on site to put the Tx 2 SN 2013393. Trip put components from three tx together. This has front panel board from Tx 1 and attenuate module from 4 dB to 1dB attenuator. Diagnostics looking good. 48-50 W fwd, 3-5W ref.
Automated Bot