Outage Information
2024-09-06 03:15:02.692000
Automatic Outage: Radials older than 12 hours. Operator should investigate.
Automated Bot

2024-09-06 12:15:03.235000
Outage cleared automatically. Radial files have caught up since initial reporting
Automated Bot

2024-11-18 21:59:11.928000
Outage closed automatically.
Automated Bot

2025-02-12 22:32:47.254000
2024-09-05 14:25:37 GMT codar Disabled transmit due to RX overheating. Likely AC issue or power related to AC. RUCODAR 2024-09-06 16:05:23 GMT codar visited site due to overheating. Found AC running, but blowing warm air and compressor fan not spinning when compressor kicked on. Contacted Dustin Martin about getting township assistance with AC swap since a lift or bucket truck is required. Handel 2024-09-26 17:24:14 GMT codar Turned off Transmitter + Receiver ports on WPS to test if overheating during the day is related. RUCODAR 2024-09-27 03:58:29 GMT codar No Bragg on Loop 1. Roarty 2024-09-27 03:58:45 GMT codar turned Rx and Tx off Roarty 2024-10-01 17:38:08 GMT codar Visited site due to overheating even though transmit was off, and also due to loss of Bragg on loop 1. Found AC blowing warm air, so I unplugged it. Then found loop 1 cable damaged by animal in small section where the cables were coiled near where the fence was. I removed the damaged section and patched the cable with M&F TNC connectors and self sealing tape, and red electrical tape, and moved the coils back to the base of the antenna. Resistances now check out and I turned transmit on temporarily and there was good Bragg on loop 1 (and L2&3). Set transmit back to OFF, but leaving all hardware ON for now. Handel 2024-10-17 18:47:41 GMT codar visited site and removed AC unit, IQ6000V16 SN# 1831224291001 and installed new IQ6000V16 SN#2441680191001. Also sprayed Duracoil on new AC cooling fins. Also swapped SSD. Handel
Teresa Updyke