Opened Outage Report
The receiver is not able to communicate with the transmitter. Remotely cycled power to both the transmitter and receiver but this did not help. Plan to visit the station on Thursday to troubleshoot.
Status switched to 'In Progress'
At the station, I found all the transmitter lights off and fans not spinning. When I removed the unit, water came out of it and I saw that the AC unit at the top of the cabinet had water dripping from a couple of the screws holding the fans in place. Sent the transmitter to CODAR for repair under RMA# 2458.
Outage cleared automatically. Radial files have caught up since initial reporting
2023-06-22 15:17:53 GMT rwsadmin (TGU) installed IOOS loan transmitter #2009257, the Haier air conditioner will not stay running, flashes a "STOP" warning, tried reseting GCI on the plug but that's not helping, same error occurs again immediately
Status switched to 'Closed'