Automatic Outage: Radials older than 12 hours. Operator should investigate.
Outage cleared automatically. Radial files have caught up since initial reporting
2022-08-22 15:40 UTC codar visited site due to no comms. found WPS tripped OFF. I reset it and everything powered up normally. I then unplugged the TrippLite from the WPS, but left everything else plugged in. The AC compressor kicked on and it's blowing cold air and the transmitter is transmitting 62W with 8W reflected for vswr of 2.1:1 @ 26.3 MHz with 0dB atten now. Handel 2022-08-22 15:54 UTC codar also enabled Autoping/power cycle on WPS for cadlepoint & 8.8.8.8. Handel 2022-08-22 18:28 UTC codar visited site for a second time today, due to no comms again. Found WPS needing to be reset again. I reset it and everything started up normally, then I switched everything off and installed a 1-to-3 plug adapter into the end of the extension cord from the building, and plugged the AC into one of its plugs and the WPS (with the rest of the hardware) into one of the other plugs, and left the third one open. Also removed previous Autoping rule just to rule that out.. Handel