Automatic Outage: Radials older than 12 hours. Operator should investigate.
Outage cleared automatically. Radial files have caught up since initial reporting
2022-05-18 18:31 UTC codar visited site due to no comms. Found web power switch ON, but not providing power through any of it's switched outlets, even though they were set to be On and the web interface and LCD interface appeared normal and set ON. Tried a brand new WPS which briefly appeared to flash On and then it stopped working except for providing power through its non-switched outlets. The APC showed no issues with local power currently, but had prior messages about distorted input. I tested the power voltage and hertz and it checked out. I replaced the WPS with a TrippLite isobar, and everything is running ok now. Handel
Status switched to 'Closed'