Outage Information
2022-01-15 21:15:02.978000
Automatic Outage: Radials older than 12 hours. Operator should investigate.
Automated Bot

2022-01-18 16:15:03.265000
Outage cleared automatically. Radial files have caught up since initial reporting
Automated Bot

2022-01-18 20:44:12.457000
site overheated and transmit tripped off, some construction work is happening at the Army Corps of Engineer's facility so this may be the cause of climate control failure
Teresa Updyke

2022-01-21 20:05:16.741000
Status switched to 'Closed'
Teresa Updyke