Outage Information
2021-07-28 04:15:03.273000
Automatic Outage: Radials older than 12 hours. Operator should investigate.
Automated Bot

2021-07-29 20:15:03.276000
Outage cleared automatically. Radial files have caught up since initial reporting
Automated Bot

2021-08-26 15:45:25.383000
2021-07-29 18:00 UTC codar visited site due to no comms with computer, although internet connection at site was up and web power switch remotely accessible. Found computer OFF, and turned it back ON manually and all programs started up normally and no error messages popped up. However, right after all SeaSonde programs finished launching the computer lost comms with the receiver. Cycling power to receiver re-established them only momentarily before they dropped out again. I then quit all SeaSonde apps and turned off the transmitter and receiver, then turned them both back on and re-launched Sentinel, and computer-rx comms were re-established without issue. Also tightened antenna anchor guy lines. Handel
Teresa Updyke

2021-08-26 15:46:53.347000
Status switched to 'Closed'
Teresa Updyke