Automatic Outage: Radials older than 12 hours. Operator should investigate.
Status switched to 'In Progress'
Outage cleared automatically. Radial files have caught up since initial reporting
Mar 29 got call from Town of Hempstead that their crew is trying to repave the walkway between our enclosure and the dune ASAP, and our cables need to be moved. Our contacts there will move the cables today, and I have turned transmit off and used WebPowerSwitch to turn off the transmitter and receiver for now. Will visit site tomorrow.Apr 28 installed all equipment, but electricians are still working on the conduit end so cables too antennas cannot yet be runJun 2 visited site and ran new tx and rx cables through new conduit under sidewalk and to respective antennas. Also removed rx #2013374 to send to codar under RMA #2315, and installed new rx # 2021620 in its place. Still using tx2 # 2014411, site now back to transmitting at 4.48MHz, using 5dB attenuation and seeing 50W out and ~3W reflected for a VSWR of ~1.65 Handel
Status switched to 'Closed'