2021-03-05 16:15:03.326000
Automatic Outage: Radials older than 12 hours. Operator should investigate.
Automated Bot

2021-03-05 23:15:02.456000
Outage cleared automatically. Radial files have caught up since initial reporting
Automated Bot

2021-03-08 16:12:55.083000
2021-03-03 18:50 UTC codar visited site due to reflected power umping up again. Suspect base collar lightning arrestor is the issue, not the feed wire, so I swapped out the tx base with a spare and went back to using inner feed wire. VSWR now back down to 1:1, ~40W out, and 0 reflected at 4.48MHz with 5dB attenuation. Handel 2021-03-05 03:07 UTC codar turned transmit off due to high reflected power. Handel 2021-03-05 19:29 UTC codar visited site due to reflected power spiking again. Swapped out tuning coil (and upper antenna section with top hat). VSWR back down to <2. Xmitting ~53W with 4dB atten. Handel
Teresa Updyke

2021-03-08 16:14:57.796000
Status switched to 'Closed'
Teresa Updyke