Outage Information
2020-09-30 06:15:02.736000
Automatic Outage: Radials older than 12 hours. Operator should investigate.
Automated Bot

2020-09-30 07:15:02.485000
Outage cleared automatically. Radial files have caught up since initial reporting
Automated Bot

2020-09-30 17:48:18.891000
2020-09-29 17:44 UTC visited site to install new APC UPS. found no power available to site upon arrival. installed and activated new UPS, and set transmit to off via software control to conserve battery life. Handel 2020-09-30 03:14 UTC power to site was restored by JCP&L, And I have set transmit back to pulse. I was also informed by JCP&L that there had been a power outage yesterday for a few hours due to a different problem that they also fixed. Handel 2020-09-30 16:50 UTC returned to site due to temperatures nearing overheating levels. found air conditioner plugged in and it's fan running, But it's digital screen and controls not functioning. I unplugged it, waited a minute, and plugged it back in and then closed the enclosure and waited a few minutes and then it sounded like the compressor kicked on and I opened the enclosure and was able to feel cool air coming out of the AC vents. perhaps the air conditioner just needed to be reset by unplugging it for a minute, but there's also a chance that it's compressor is starting to fail or it's electrical control circuits are starting to fail. Will monitor temperature diagnostics closely over the next few days. Handel
Teresa Updyke

2020-09-30 17:48:29.006000
Status switched to 'Closed'
Teresa Updyke