Outage Information
2020-08-20 09:15:02.458000
Automatic Outage: Radials older than 12 hours. Operator should investigate.
Automated Bot

2020-08-24 18:15:02.516000
Outage cleared automatically. Radial files have caught up since initial reporting
Automated Bot

2020-09-04 19:39:07.338000
2020-08-24 15:57 UTC codar visited site due to computer unable to detect receiver. power cycling receiver fixed issue. setup WebPowerSwitch to allow for future receiver power cycling to be done remotely. Handel
Teresa Updyke

2020-09-04 19:40:19.356000
Status switched to 'Closed'
Teresa Updyke