2020-03-27 14:40:01.297000
Opened Outage Report
Teresa Updyke

2020-03-27 14:40:01.297000
losing connection to receiver, problem persisted after replacing receiver front panel board
Teresa Updyke

2020-04-09 13:03:05.523000
On Mar 30, installed Tripplite Isolator on site to help condition the incoming power. On Apr 7, moved all equipment to the office for bench testing. Still cannot connect to receiver, even with direct USB connection to AWG module inside chassis. Will try replacing the AWG module.
Teresa Updyke

2020-04-09 13:03:30.394000
Status switched to 'In Progress'
Teresa Updyke

2020-04-09 21:04:42.913000
The AWG module and front panel board were both ok when installed in a 25 MHz chassis. Something else inside the receiver is not working. Shipped the unit back to CODAR RMA #2253
Teresa Updyke

2020-04-09 21:06:15.681000
An IOOS loan is not available at this time.
Teresa Updyke

2020-04-16 12:01:55.514000
Installed rx 2005127 and tx 2005127 taken from CEDR
Teresa Updyke

2020-04-16 12:04:43.669000
Status switched to 'Closed'
Teresa Updyke