Outage Information
2025-05-09 04:15:08.393000
Automatic Outage: Radials older than 12 hours. Operator should investigate.
Automated Bot

2025-05-16 05:16:07.349000
2025-05-15 16:02:38 GMT codar visited site due to receiver 24v and 5v voltages dropping to zero and site unable to transmit or collect Bragg. I removed RX #2004149 and installed RX # 2013374 and Bragg and power out now looking good. I also finished updating and configuring the computer to macOS 15.5 and installed and configured Radial Suite R24. I also removed transmitter #2013404 due to it being a TX2 unit and installed TX #200043. I also vacuumed out enclosure. Handel
Automated Bot

2025-05-17 05:15:27.850000
2025-05-16 13:38:58 GMT codar Created new AngSeg_AMAG file. Handel
Automated Bot

2025-05-20 05:15:25.766000
2025-05-19 16:12:15 GMT codar processed and installed new PFS APM using 120 Simple Loops and 10 degrees of smoothing. Set phases to -160, -137 per phases.txt. Site requires AIS software update from CODAR to process AIS APMs and AIS Loops and even Auto APMS. Stolarz
Automated Bot

2025-05-21 05:15:23.516000
2025-05-20 17:39:15 GMT codar COS ML: installed AIS R22u2, set Bearing limits to 90,260. Disabled Sentinel under Old_Codar.
Automated Bot

2025-05-29 16:15:26.463000
Outage cleared automatically. Radial files have caught up since initial reporting
Automated Bot