Automatic Outage: Radials older than 12 hours. Operator should investigate.
Outage cleared automatically. Radial files have caught up since initial reporting
2024-11-06 16:41:58 GMT codar increased non-flagged area in AngSeg from 75-155º to 75-175º to try and increase coverage towards south. Handel
2024-11-12 15:13:39 GMT codar site was off due to a power outage, but now operating normally. Handel
2024-11-14 20:17:10 GMT codar Visited site and lowered receive antenna in order to clean the top threads and apply and self ceiling tape and electrical tape. Antenna base could be moved further towards the ocean and higher onto the Dune. Also painted enclosure platform. Handel
2024-11-18 16:55:14 GMT codarprocessed and installed new AutoAPM which had 16 degrees of smoothing. Set phases to -144, -152. Handel & Stolarz
Outage cleared automatically. Radial files have caught up since initial reporting