Outage Information
2024-07-11 05:15:03.698000
Automatic Outage: Radials older than 12 hours. Operator should investigate.
Automated Bot

2024-07-11 17:52:51.700000
Loop 2 resistance at the dome is low, only 100 ohms. Requested CODAR RMA.
Teresa Updyke

2024-07-11 17:53:22.239000
Status switched to 'In Progress'
Teresa Updyke

2024-07-15 13:20:54.478000
Shipped to CODAR on July 12 under RMA#2533
Teresa Updyke

2024-07-24 15:53:09.107000
2024-07-23 16:08:16 GMT installed IOOS loan antenna but found weak signal on channel 2, the resistance reading from the bottom of the mast is good (3047 ohms), but I tested the loop 2 cable from the bottom of mast to the chassis with a 50 ohm resistor and it was bad (400 ohms at first then saw readings in the megaohms range)
Teresa Updyke

2024-08-12 18:15:08.827000
Outage cleared automatically. Radial files have caught up since initial reporting
Automated Bot

2024-08-17 00:33:47.384000
Replaced a section of the loop 2 cable that was damaged.
Teresa Updyke

2024-08-17 00:33:57.173000
Status switched to 'Closed'
Teresa Updyke