Outage Information
2023-08-15 08:15:03.675000
Automatic Outage: Radials older than 12 hours. Operator should investigate.
Automated Bot

2023-08-17 20:15:03.424000
Outage cleared automatically. Radial files have caught up since initial reporting
Automated Bot

2023-08-28 15:41:18.345000
2023-08-14 19:42:40 GMT codar visited site due to high reflected power. All connections in transmit line were tight and in good shape, so we tried swapping out dome #2014219 and installing dome #570. High reflected power remains. Leaving transmit off for now. Handel & Stolarz 2023-08-17 19:22:57 GMT codar Visited site due to persistence of high reflected power even after swapping antennas from dome #2014219 to dome #570. Found issue was in the top whip so the top whip was replaced and dome antenna #2014219 was reinstalled. New sighting was obtained and set at 135 deg magnetic. Dome #570 is going back to Rutgers. Removed broken ventilation fan on side of shed and installed new fan. Edges of fan outside shed was taped to help insulate the shed and keep out environment. Trimmed bushes near guy lines. Handel & Stolarz
Hugh Roarty

2023-08-28 15:41:47.199000
Status switched to 'Closed'
Hugh Roarty