Outage Information
2023-06-09 03:15:02.959000
Automatic Outage: Radials older than 12 hours. Operator should investigate.
Automated Bot

2023-08-14 15:13:27.934000
2023-06-08 15:56:50 GMT codar visited site and removed antenna #2014220 to send back to codar under RMA # 2456 due to loop2 low SNR and distortion of pattern, visible corrosion. Also removed TX & RX pair # 2011336 for now. Handel
Hugh Roarty

2023-08-14 15:14:00.195000
Status switched to 'In Progress'
Hugh Roarty

2023-10-25 19:15:03.254000
Outage cleared automatically. Radial files have caught up since initial reporting
Automated Bot

2024-02-07 00:46:24.298000
antenna failed
Hugh Roarty

2024-02-07 00:46:36.444000
Status switched to 'Closed'
Hugh Roarty