Outage Information
2023-05-30 21:04:07.035000
Opened Outage Report
Teresa Updyke

2023-05-30 21:04:07.036000
The receiver is not able to communicate with the transmitter. Remotely cycled power to both the transmitter and receiver but this did not help. Plan to visit the station on Thursday to troubleshoot.
Teresa Updyke

2023-05-30 21:04:27.537000
Status switched to 'In Progress'
Teresa Updyke

2023-06-08 02:23:41.195000
At the station, I found all the transmitter lights off and fans not spinning. When I removed the unit, water came out of it and I saw that the AC unit at the top of the cabinet had water dripping from a couple of the screws holding the fans in place. Sent the transmitter to CODAR for repair under RMA# 2458.
Teresa Updyke

2023-06-22 16:15:03.773000
Outage cleared automatically. Radial files have caught up since initial reporting
Automated Bot

2023-08-01 19:59:16.515000
2023-06-22 15:17:53 GMT rwsadmin (TGU) installed IOOS loan transmitter #2009257, the Haier air conditioner will not stay running, flashes a "STOP" warning, tried reseting GCI on the plug but that's not helping, same error occurs again immediately
Teresa Updyke

2023-08-01 19:59:23.828000
Status switched to 'Closed'
Teresa Updyke