Automatic Outage: Radials older than 12 hours. Operator should investigate.
2023-03-29 15:20 UTC Investigated site due to sudden loss of signal in loops 1 and 2. Found the cables had been cut during tree trimming. Will require repair in near future. Disabled transmit until repair. Set up computer for radial suite upgrade. Stolarz
Status switched to 'In Progress'
Outage cleared automatically. Radial files have caught up since initial reporting
Repaired loops 1 + 2 cables by replacing with 2 M + 2 F TNC connectors. Bragg now seen in loops 1 + 2. Slack taken from flagged spot near telephone pole. Loops labeled with corresponding red and blue tape. Buried part of cable under new trailing running parallel to the beach at the back of the hill the antenna is on. Further slack needed might require re-reunning new cable. Handel & Stolarz 2023-04-04 12:59 UTC codar site had not been making radials since yesterday's cable repairs. Ran script to clean out the processing folder and then restarted computer. Handel 2023-04-04 14:34 UTC codar Rechecked on site radial generation, was still suspended due to AnalyzeSpectra terminal not running. Clicked on AnalyzeSpectra.term to run the script and radial generation has resumed. Handel & Stolarz
Status switched to 'Closed'