Outage Information
2022-12-16 11:15:03.239000
Automatic Outage: Radials older than 12 hours. Operator should investigate.
Automated Bot

2022-12-16 17:15:03.031000
Outage cleared automatically. Radial files have caught up since initial reporting
Automated Bot

2022-12-19 15:40:44.415000
phase change caused the measured to no longer be usable. will need to redo pattern.
Hugh Roarty

2022-12-19 15:49:26.393000
computer lost comms with Rx. site had lost connection between receiver and computer. Used WPS to turn off power to both of their outlets and then back on and that resolved the issue for now. Handel
Hugh Roarty

2022-12-19 15:49:39.265000
Status switched to 'In Progress'
Hugh Roarty

2022-12-19 16:15:02.914000
Outage cleared automatically. Radial files have caught up since initial reporting
Automated Bot

2022-12-20 15:36:42.353000
2022-12-16 15:50 UTC codar site had lost connection between receiver and computer. Used WPS to turn off power to both of their outlets and then back on and that resolved the issue for now. Handel
Teresa Updyke

2022-12-20 15:36:53.407000
Status switched to 'Closed'
Teresa Updyke