Outage Information
2022-04-24 06:15:02.456000
Automatic Outage: Radials older than 12 hours. Operator should investigate.
Automated Bot

2022-05-03 19:19:37.270000
Outage cleared automatically. Radial files have caught up since initial reporting
Automated Bot

2022-06-29 13:09:14.950000
2022-04-28 15:12 UTC codar visited site due to no comms. found no power in shed. turns out there had been a water leak in seaport pier that caused flooding in the police substation room where the breaker panel that our shed's circuit runs to is, and that panel was shut off while things dried. I was able to get Doug Ford to send an electrician over to confirm the flooding was gone and it was safe to restore power, and he did, and all equipment power back n]up normally. preformed 6mo inspection and swapped out external CodarArchives SSD. Handel
Teresa Updyke

2022-06-29 13:09:32.993000
Status switched to 'Closed'
Teresa Updyke