Outage Information
2021-08-01 14:15:03.044000
Automatic Outage: Radials older than 12 hours. Operator should investigate.
Automated Bot

2021-08-01 18:15:02.447000
Outage cleared automatically. Radial files have caught up since initial reporting
Automated Bot

2021-08-31 21:42:51.387000
2021-08-02 19:30 UTC codar visited site due to high reflected power and lack of Bragg on loop 3. upon inspection found loop 3 ferrite cable damaged near female N-connector. removed damaged section and re-terminated choke cable. vswr back down to ~1:1 and Bragg looks good. also had to unplug CodarArchives SSD and replug it in to re-establish connection to computer. Handel
Teresa Updyke

2021-08-31 21:43:08.830000
Status switched to 'Closed'
Teresa Updyke